MI 3152(H)
Eurotest
XC (2,5 kV)
Instrument operation
27
4.4.2 Battery indication
The battery indication indicates the charge condition of battery and connection of external
charger.
Battery capacity indication.
Battery is in good condition.
Battery is full.
Low battery.
Battery is too weak to guarantee correct result. Replace or recharge the
battery cells.
Empty battery or no battery.
Charging in progress (if power supply adapter is connected).
4.4.3 Measurement actions and messages
Conditions on the input terminals allow starting the measurement. Consider
other displayed warnings and messages.
Conditions on the input terminals do not allow starting the measurement.
Consider displayed warnings and messages.
Proceeds to next step of the measurement.
Stop the measurement.
Result(s) can be stored.
Starts test leads compensation in Rlow / continuity measurement.
Starts Zref line impedance measurement at origin of electrical installation in
Voltage Drop measurement. Zref value is set to 0.00 Ω if pressing this touch
key while instrument is not connected to a voltage source.
Use A 1199 Specific earth resistance adapter for this test.
Use A 1143 Euro Z 290 A adapter for this test.
Use A 1172 or A 1173 Illumination sensor for this test.
Count down timer (in seconds) within measurement.
Measurement is running, consider displayed warnings.
RCD tripped-out during the measurement (in RCD functions).