PROTON 206/308 V1 System Manual
73
Packaging
Toll Control
What’s this?
Toll Control can:
•
Restrict dialing all local telephone numbers.
•
Restrict dialing certain local telephone numbers.
•
Restrict dialing telephone nos. starting with ‘95’.
•
Restrict dialing certain areas (area codes 03 and 04).
•
Allow dialing only certain telephone number. (2630555)
•
Allow dialing only certain area code.
•
Allow dialing only those telephone numbers starting with particular digit. (1)
How it works?
•
The PROTON 206/308 uses Allowed and Denied Lists to support this feature.
•
When a call is made, the PROTON 206/308 compares each digit of the dialed number string with the number
strings in allowed and denied list.
•
If the dialed number string matches with any of the number strings available in allowed list, the PROTON
206/308 dials the number on the trunk, else compares with the number strings in the denied list.
•
If the dialed number string matches with any of the number strings available in denied list, the PROTON 206/
308 restricts dialing the number and gives error tone to the station user.
•
If the dialed number matches with a number string that is available in both allowed and denied lists then
allowed list is given priority and the dialed number is dialed on the trunk.
How to use it?
•
By default, few number strings are available in the allowed and denied lists. If these number strings satisfy
the requirement then these should be assigned to the station for day time and night time.
•
If the requirement is not met by default allowed and denied list then customized allowed and denied lists
should be programmed.
•
The number strings which are to be allowed should be programmed as allowed strings.
•
The number strings which are to be denied should be programmed as denied strings.
•
One such allowed-denied list (level) should be assigned to each station for day time and night time
individually.
•
If customized toll control is to be provided then customized numbers should be programmed as allowed
strings and denied strings. For example, the requirement is that station 21 can make a call to Mumbai (022)
but should not make any other long distance call. In this case, number string 022 should be programmed in
one of the locations of the allowed strings and number string ‘0’ should be programmed in one of the
location of denied string and this allowed/denied list (level) should be assigned to station 21.
•
One such allowed-denied list (level) should also be assigned to the station for the locked condition.
•
Once the station has been locked, the station user can make calls as per the allowed-denied lists (level)
assigned to the station for the locked condition. This is called Dynamic Toll Control.
•
Allowed-Denied list 0 (level 0) is assigned in locked condition by default.
Operating Humidity
5-95% RH, non-condensing
Storage Temperature
-40°C to +85°C (-40°F to 185°F)
Storage Humidity
0-95% RH, non-condensing
Dimensions (W x H x D)
26x28x7.5 cm, 10.24x11.02x2.95 Inch
Unit Weight
1.3 Kg. (2.8lbs)
Installation
Wall Mountable
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...