24
PROTON 206/308 V1 System Manual
•
If CDC is activated, then system gives warning beeps after time = CDC warn timer. After the warning tone,
the system waits for time = CDC good-bye timer before releasing the connection forcefully.
•
CDC can be activated on selected stations.
•
CDC can be activated for either day, or night, or both.
•
In case of transferred call, the CDC timer gets reset and starts again afresh on the transferred station.
•
It is also possible to just warn the user without disconnecting his call. In this case, the user gets the beeps
after the programmed time but his call does not get disconnected.
•
If Barge-in/Raid feature is used on a station on which CDC is activated then the time for which Barge-In/Raid
was done will not be counted.
How to program?
Step 1:
Enable/disable CDC for local calls using command
3331.
Step 2:
Enable/disable CDC for STD call using command
3332.
Step 3:
Enable/disable CDC for incoming calls using command
3333.
Step 4:
Enable/disable CDC warning beeps without disconnection using command
3334.
Step 5:
Set various timer for CDC.
Step 1
Use following command to enable/disable CDC for local calls:
3331-Station-Day Time-Night Time
Where,
Station is from 21 to 28.
Use following command to enable/disable CDC for Local calls for all stations:
3331-*-Day Time-Night Time
By default, CDC for local calls is disabled during day time and night time.
Step 2
Use following command to enable/disable CDC for STD calls:
3332-Station-Day Time-Night Time
Where,
Station is from 21 to 28.
Use following command to enable/disable CDC for STD calls for all stations:
3332-*-Day Time-Night Time
By default, CDC for STD calls disabled during day time and night time.
Day Time
Night Time
Meaning
0
0
CDC is disabled
1
1
CDC is enabled
Day Time
Night Time
Meaning
0
0
CDC is disabled
1
1
CDC is enabled
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...