PROTON 206/308 V1 System Manual
49
Important Point:
•
The stations having access to trunk and higher toll control will only be able to make external calls.
Relevant Topics:
1.
2.
External Call Forward (ECF)
What’s this?
It is possible to divert the calls on your personal trunk line to your residence or your mobile number. This facility
of diverting your incoming trunk calls is known as External Call Forwarding or ECF in short.
How to program?
Step 1:
Decide the trunk of which the calls are to be forwarded.
Step 2:
Assign a destination trunk for the ECF trunk.
Step 3:
Assign the destination number where the calls are to be forwarded.
Step 1
Use following command to enable/disable ECF on a trunk:
521-Trunk-Day Time-Night Time
Where,
Trunk is from 1 to 3 of which the calls are to be forwarded.
By default, ECF is OFF on all the trunks.
Step 2
Use following command to assign destination trunk to forward the calls of a trunk:
522-Trunk-Destination Trunk
Where,
Trunk is 1 to 3 of which the calls are to be forwarded.
Destination trunk from 1 to 3 or 0 or 5. It signifies the trunk to be used by the PBX to dial out the telephone
number. If 0 or 5 programmed as destination trunk then any of the free trunks from group 0 or group 5 would be
used for out dialing.
Step 3
Use following command to assign destination number where the calls are to be forwarded for a trunk:
523-Trunk-Telephone Number-#
Where,
Trunk is 0, 5, 1, 2, or 3 of which the calls are to be forwarded.
Telephone Number is the number (maximum 16 digits) where the calls are to be forwarded.
Example:
Program ECF on trunk 1 during night time. Destination trunk can be any free trunk from group ‘0’. The calls are
to be forwarded to ‘2359695’.
521-1-0-1
522-1-0
523-1-2359695-#
Day Time Night Time Meaning
0
0
ECF Disable
1
1
ECF Enable
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...