46
PROTON 206/308 V1 System Manual
Station is from 21 to 28.
By default, DOSA is disabled on all stations.
Example:
Disable DOSA from station 23 on trunk 2 during day time enable it during nighttime.
Use following command to satisfy the requirement:
35-23-1
45-2-0-1
Step 3
Use following command to program DOSA Inactivity Timer in Second/Minute:
207-Code
Where,
Step 4
Timer of Relevance:
DOSA Inactivity Timer
-Time after which the system gives warning beeps to the caller:
Command :
216-Seconds
Default : 30 seconds
Valid Range : 00 to 99 seconds.
For DOSA Music Timer and DOSA Beep Timer. Please refer ‘
Important Points:
•
DOSA facility can be enabled on one or more trunks.
•
DOSA can be enabled/disabled for Day and Night times independently.
•
DOSA inactivity timer is the time for which a line remains active even after the call is finished if the user
forgets to log out by dialing ‘
#
’. Hence it is advisable to program this timer for optimum period.
•
Because of poor line conditions, it is possible that DOSA facility may not work.
DOSA facility allows remote users to make long distance calls. It is advisable for all the users to
understand the power and cost implication of this facility and hence enable this facility very carefully. It
is strongly recommended to protect this facility with a unique password.
Relevant Topics:
1.
2.
“Direct Inward Dialing (DID)” 43
Distinctive Rings
What’s this?
The PROTON 206/308 support different types of ring for different situations.
Code
Meaning
0
DOSA Disable
1
DOSA Enable
Code
Meaning
0
DOSA Inactivity Timer in Second
1
DOSA Inactivity Timer in Minute
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...