62
PROTON 206/308 V1 System Manual
•
Main operator station
•
Secondary operator station
How it works?
•
When any station presses ‘9’ the system diverts the call to the main operator.
•
If main operator is absent the call is diverted to the secondary operator.
How to program?
Use following command to program the Main Operator station:
391-Station
Where,
Station is from 21 to 28.
Use following command to program Secondary Operator station:
392-Station
Where,
Station is from 21 to 28.
Example:
Program station 23 as a main operator and station 24 as a secondary operator.
391-23
392-24
Relevant Topic:
1.
Power Down Mode
What’s this?
During power failure, it is desirable to have trunk lines available directly on few stations. This is known as Power
Down Mode. When mains power returns, normal operation resumes. Change over from normal to power down
operation and back is automatic.
During power down mode, by default, Trunk 1 gets connected to station 21, Trunk 2 gets connected to station
22, whereas Trunk 3 gets connected to station 23. At the time of Power failure/Power return ongoing calls gets
disconnected.
During power failure condition, calls can be made from these stations. Also the incoming calls lands on
respective stations. This way, your link with the outside world is retained even during dark-outs.
How it works?
Following block diagram shows the power fail transfer function for one port:
Figure 1: Power Fail Condition Figure 2: Normal Condition
Telephone
connection
in the field
Station
Circuit
Trunk Line
Power fail Transfer for One Port
C
C
NO
NC
NC
NO
Telephone
connection
in the field
Station
Circuit
Trunk Line
Power fail Transfer for One Port
C
C
NO
NC
NC
NO
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...