78
PROTON 206/308 V1 System Manual
Use following command to assign same hunting scheme for daytime and nighttime to all the trunks:
46-*-Day Hunting Scheme-Night Hunting Scheme
Timer of Relevance:
Hunt Timer
-Time for which the station rings when an incoming call lands on it. It is relevant in case of Round
Robin and delayed simultaneous type of hunting scheme.
Command :
212-Timer
Default : 18 seconds
Valid Range : 01 to 99 seconds.
Example:
Program the system so that the call on trunk 1 lands in round robin fashion on stations 21, 22, 23, 24 and 25
during daytime and simultaneously on these stations during nighttime.
47-1-21-22-23-24-25
48-1-21-22-23-24-25
46-1-1-3
Relevant Topics:
1.
2.
3.
Trunk Parameters
What’s this?
•
A trunk can individually be enabled or disabled. When the PROTON 206/308 is being used with only one
trunk line the other trunk port must be disabled. This can be useful when a particular trunk goes out of order
and should be stopped from being allocated to a user when he dials common trunk access code ‘0’.
•
A trunk can be programmed as Tone type and Pulse type.
How to program?
Use following command to Enable/Disable the trunk and set Dial type:
41-Trunk-Enable/Disable-Pulse/Tone
Where,
Trunk is 1, 2 or 3.
By default, all trunks are enabled and programmed as tone type.
Use following command to Enable/Disable and set Dial type on all trunks:
41-*-Enable/Disable-Pulse/Tone
Timers of Relevance:
Class of Service Delay Timer
-It is the time after which you get P&T dial tone on dialing ‘0’ or ‘5’ or ‘61’ or ‘62’ or
‘63’. This ensures dialing and storage of complete string of telephone number by the PBX.
Command:
531-Trunk-Seconds
Default: 01 second.
Enable/Disable Meaning
0
Trunk is disabled
1
Trunk is enabled
Pulse/Tone Meaning
0
Trunk is programmed as Pulse type
1
Trunk is programmed as Tone type
Summary of Contents for Proton 206
Page 1: ...PROTON 206 308 System Manual ...
Page 2: ......
Page 3: ...PROTON 206 308 The Smart Communicator System Manual ...
Page 8: ...8 PROTON 206 308 V1 System Manual ...
Page 86: ...86 PROTON 206 308 V1 System Manual ...
Page 92: ...92 PROTON 206 308 V1 System Manual ...
Page 96: ...96 PROTON 206 308 V1 System Manual W Walk In Class of Service 85 X Y Z ...