Patch
38
Xciter user manual
8.2
Patch
Before you start programming, Xciter needs to know which devices are connected to its DMX universe and
how it will control them. This is where the patch comes in. To patch a device means to connect it to the
Xciter controls, so you are able to manipulate it.
The Xciter controls are divided into three groups, which enable you to control:
•
Up to 40 fixtures.
•
Up to 20 dimmers.
•
Up to 4 direct access devices.
Press {Patch} in the setup menu to access the patch menu.
8.2.1
Selecting a patch
Since Xciter can store up to 160 patches, each show can have its own patch assigned to it. Xciter is set up
with one patch per show by default. This means that, when you select another patch number, Xciter uses
the patch for the current show. The default patch number is the same as the show number in the intro
screen.
If you use the same lighting rig in multiple shows, you will want to use the same patch in those shows.
Xciter lets you reuse one patch in multiple shows by reassigning it to those shows.
Example: Show 102 is the current show. By default it has patch 102 assigned to it. We wish to use patch
101 on that show (same patch as show 101).
1.
Press {Patch#} in the patch menu. By default, the patch has the same number as the selected show.
2.
Use page keys 1-8 and general-purpose number keys 1-20 to select patch 101.
In our example, patch 101 already has content. If a patch has content, Xciter will give you the option to copy
the content of the current patch into another patch. We will explain this later.