Part Number 020002365 08/25/2015 19
Section 2
Installation
CO
2
Gas and Compressed Air Circuit Diagram
Carbonator Ta
nk “B”
Legend
— Manual Shut-o
ff V
alv
e
— Check V
alve, Ball
Ty
pe
— Manual 3-way Ball V
alv
e
— Connection for Optional Kits
Carbonato
r
Tank “A”
Sugar Free Line & Disconnec
t
Sugar Base Lines & Disconnects
Sugar Base Lines & Disconnects
Optional Air/CO
2
Change
-
over V
alv
e
Optional
CO
2
Change-over
Va
lv
e
AB
Optional
Air Compresso
r
Optional Bulk CO
2
T
ank
Set at 90-100 psi
(6.2-6.9 bar
)
Optional CO
2
T
ank
“A”
Optional CO
2
T
ank
“B”
Pressure Switch
“ON” = 70 psi (4.8 bar
)
“OFF” = 90 psi (6.2 bar
)
Shak
e
Machin
e
CO
2
Shut-o
ff to
Carbonator
Tank
Medium Pressure Regulator
Set at 60 psi (4.1 bar
)
Low Pressure Regulator
Set at 15 psi (1 bar
)
Shake Machine Shut-o
ff V
alv
e
Optional CO
2
Regulator
s
Set at 90-100 psi
(6.2-6.9 bar
)