Part Number 020002365 08/25/2015 35
Section 3
Operation
PROGRAM MODE 4
Temporarily cancel display of error codes. Cancelling the
error codes allows circulating glycol temperatures to be
displayed until the error can be corrected.
• Press
PGM
button for 3 seconds - Display shows
0001
.
• Press
PGM
button three times in less than 3 seconds -
Display shows
0004
program mode 4.
• Wait 3 seconds - Display shows
-004
= All error codes
will be displayed during run mode (Factory Default).
• Press
COMP/AGIT
button once - Display shows
---4
=
error codes will not be displayed during run mode.
NOTE: Disconnecting and reconnecting main power will
reset the control board to the factory setting
-004
= Error
codes will be displayed in the run mode.
• Press and hold
PGM
switch for 3 seconds to save
settings and exit program mode.
PROGRAM MODE 5 (G SERIES MODELS)
Energy-Saving Program Mode
ERC Control (020001985) - Must be Hardware version 4.0 or
greater, Software version 3.19 or greater.
• Press
PGM
button for 3 seconds - Display shows
0001
.
• Press
PGM
button four times in less than 3 seconds -
Display shows
0005
program mode 5.
NOTE: If
0005
fails to display, you have an incompatible
version of the ERC control board and this mode is not
available.
• Wait 3 seconds or until the display shows
-X-5
• Press
COMP/AGIT
button to enable/disable energy
savings mode.
A.
-o-5
= Energy savings mode enabled
B.
---5
= Energy savings mode disabled
• Press and hold
PGM
switch for 3 seconds to save
settings and exit program mode. All changes
permanently saved and display will revert back to
normal run mode
ERC Operation in Mode 5
Circulating motor LED will flash once per second if energy
saving PGM mode 5 is enabled. The LED will stay constantly
ON if energy saving PGM mode 5 is disabled.
ERC control monitors all carb motors for entering energy
savings cycle mode. If no carb cycles in 30 minutes, no
ERC error codes or sensors open / shorted, and circulating
temperature = < 3.3°C (38°F), then energy savings cycle
mode will be entered.
NOTE: Display adds “o” to left digit to indicate in energy
savings cycle mode “oxxc” (Centigrade) “oxxF” (Fahrenheit)
1. If circ temp = <2.2°C (36°F), energy savings cycle mode
off time is 10 minutes.
2. If circ temp = <2.8°C (37°F) and >2.2°C (36°F), energy
savings cycle mode off time is 8 minutes.
3. If circ temp = <3.3°C (38°F) and >2.8°C (37°F), energy
savings cycle mode off time is 6 minutes.
4. If circ temp = >3.3°C (38°F), then no energy savings
cycle mode entered.
Agitator and circulator will be turned off when in energy
savings cycle mode off-time.
When energy savings cycle mode off-time is completed,
agitator and circulator motors will be turned on in energy
savings cycle mode on-time.
Motors will stay on until temperature entered is reached:
(<2.2°C (<36°F), >2.2-2.8°C (36-37°F), >2.8-3.3°C (37-38°F)
Energy savings cycle mode will repeat (off time 10, 8, 6
minutes depending on entering temperature, then on
again until entering temperature is reached).
Energy savings cycle mode is exited when:
ū
Any carb cycle occurs
ū
Any error code occurs
ū
Circulating temperature exceeds 3.3°C (38°F)
Display changes to normal run mode, and circulating LED
flashes for controlled ON. System waits for another 30
minute period without carb cycle to enter energy savings
cycle mode again.