Part Number 020002365 08/25/2015
Troubleshooting
Section 5
Error Notes
• Error codes will interrupt the temperature display and
stay active until the error is corrected.
• If multiple errors are present, the errors will rotate and
display every 5 seconds.
• Resetting errors — After correcting the problem, the
respective switch for the error must be cycled OFF and
then ON to reset.
• Disconnecting and reconnecting power will erase all
errors.
Error Code
Error
Cause
E1
Low Water Supply Pressure
Lower than 5 psi for 5 Seconds
E2
Low CO
2
Pressure
Lower than 10 psi for 5 Seconds
E3
Low Water Level – Water Bath
Must Cover Top of Evaporator - Water Level Probe
Mounted Too High
E4
High Water Bath Temperature
Water Bath Temperature Greater Than 45°F
E5
High Water Supply Pressure
Water Pressure Greater than 75 psi
E6
High Refrigeration Temperature
Discharge Line Temperature Greater than 190°F
E7
High Ice Bank Size
Ice Contacting Center Ice Bank Probe
E8
Long Carb A Run Time
Energized for 7 Continuous Minutes
E9
Long Carb B Run Time
Energized for 7 Continuous Minutes