48
Part Number 020002365 08/25/2015
Troubleshooting
Section 5
E4, E5, & E6 Flowchart
EI
E2
E3
E4
E5
E6
E7
E8
E9
NORMALLY CAUSED BY WATER
BATH TEMPERATURE > 45°F
NORMALLY CAUSED BY WATER
PRESSURE >75 PSI,
NORMALLY CAUSED BY LIQUID
SIDE TEMPERATURE>200°F
NO
YES
NO
YES
GO INTO PROGRAMMING MODE
1, “F000”PRESS CARB A BUTTON
TO SHOW WATER BATH
TEMP“FXXX” °F
GO INTO PROGRAMMING MODE
1, “P000”PRESS CARB A BUTTON
TO SHOW INCOMING WATER
PRESSURE “PXXX” PSI
GO INTO PROGRAMMING MODE
1, “F000”PRESS CIRC A BUTTON
TO SHOW LIQUID LINE TEMP
“FXXX” °F
WATER BATH
TEMP DISLAY
NO
YES
WATER PRESS
>75 PSI
NO
>45 °F
YES
NO
YES
YES
NO
LIQUID LINE
TEMP >200°F
VERIFY TEMP WITH SECOND
THERMOMETERIF STILL
<45°FREPLACE ERC BOARD
VERIFY PRESSURE WITH
SECOND PRESS GAUGE
VERIFY TEMPERATURE WITH
SECOND TEMP GAUGE
020001985
PRESSURE
VERIFIED
TEMPERATURE
VERIFIED
VERIFY TEMPERATURE
WITH SECOND
THERMOMETER
TROUBLE SHOOT WATER
SUPPLY SYSTEM TO FIX.
HIGH WATER PRESS,
REGULATOR BAD, NEEDED
FIRST CHECK FOR
CONDENSER FAILURE OR HOT
GAS BYPASS
TEMPERATURE
VERIFIED
GO TO COMPRESSOR /
REFRIGERATION SYSTEM
TROUBLESHOOTING
REPLACE WATER
PRESSURE TRANSDUCER
020001992
GO TO COMPRESSOR
TROUBLESHOOTING TO FIX
REFRIGERATION SYSTEM
REPLACE DISCHARGE/LIQUID
LINE TEMPERATURE
THERMISTOR 020001991
VERIFY TEMP WITH SECOND
THERMOMETERIF STILL <200°F
REPLACE ERC CONTROL
BOARD 020001985
VERIFY PRESS WITH
SECOND GAUGE, IF
CORRECTREPLACE ERC
BOARD 020001985
REPLACE WATER BATH
THERMISTOR
020002142