Part Number 020002365 08/25/2015 25
Section 2
Installation
ROUTING INSULATED CONDUIT
1. Before connecting conduit, evaluate store situation and
lay out how the conduit will be routed. Be sure to route
conduit away from traffic areas, moving parts, and heat
sources.
2. Physically route conduit per evaluated plan. Examine
conduit routing and check for neatness, kinks, and
interferences.
CONNECTING INSULATED CONDUIT AT THE UNIT
NOTE: List what color line was connected to which product
so it can be connected correctly at the towers.
1. Route the conduit to the front opening and into the
unit. Cut the insulation back from the lines inside the
water bath.
2. Connect the circulating water by connecting one line
to the circulating pump outlet line (3/8” barb) and
clamp in place. Connect the other line to the bulkhead
return fitting located by the agitator motor (3/8” barb)
and clamp in place.
CONNECTING INSULATED SUPPLY LINES
Connecting the insulated beverage conduit at the
refrigeration unit
1. Route the Multipar beverage conduit from the
refrigeration unit to the dispensing station(s) according
to the instructions enclosed with the conduit kit.
Always route the conduit in a neat and orderly manner.
2. Insert the Multipar conduit into the outlet opening
on the left hand side of unit. Conduit insulation must
extend inside of opening in unit for proper operation of
equipment.
Insulated
Beverage
Conduit
NOTE: Multipar conduit is color coded for easy identification
of lines. When making connections always attach lines
requiring the longest connection from the insulation first.
The remaining lines can be trimmed as required to make
the routing neat and secure.
3. Locate the two blue carbonated water lines of the
Multipar conduit. Attach one of the blue lines to the tee
fitting located on top of the carbonator tank. Attach
the other blue line to John Guest elbow fitting on the
stainless coil labeled “8”.
4. Locate the black plain water line of the Multipar
conduit. Attach this line to the elbow fitting on the
stainless coil labeled “W”.
5. The remaining lines of the Multipar conduit are syrup
supply lines and must be attached to the appropriate
elbow fittings on stainless steel syrup coils. Note the
numbered lines attached to the opposite end of each
syrup coil when making connections.