Part Number 020002365 08/25/2015 21
Section 2
Installation
POSITIONING OF REFRIGERATION UNIT
Before proceeding with installation, verify that all
requirements for roof mounted Remote Condenser units
have been satisfied (if applicable). Refer to the instructions
on installing the Remote Condenser supplied with the unit.
If unit is to rest on floor, locate four 6” (15.2 cm) adjustable
legs (optional). Screw and tighten legs into the bottom of
the refrigeration unit. Set unit in desired location and adjust
legs until unit is level and sturdy. If unit is to be mounted
on stand, position stand and secure unit to stand. If unit is
to be installed on a wall mount bracket, install wall mount
bracket and position unit on bracket at this time. Fasten
unit to bracket with bolts provided.
EQUIPMENT PLACEMENT
NOTE: All Refrigeration Units must be mounted on either 6"
legs or optional stand.
1. Move the stand/refrigeration unit to the designated
area and position it near the wall at a distance of at
least 6" (15.2 cm) for air circulation in air-cooled units,
or at a distance required by local code.
2. Level the stand/unit by adjusting the leg levelers
provide on the legs or stand.
3. If unit is equipped with optional stand, lift the
Refrigeration Unit onto the stand. Position the unit in
the center of the stand. Be sure to orientate the drain
of the refrigeration unit with the drain access hole of
the stand. Secure with 5/8"-11 x 1" bolts supplied in
kit, use two (2) bolts diagonally. Schedule the plumber
and electrician to connect the water supply and
electrical service if you have not already done so (refer
to Electrical Requirements and Plumbing Requirements
for plumbing and electrical requirements listed in these
instructions).
4. Mount any optional equipment at this time. Follow the
installation instructions for each kit required.
ELECTRICAL CONNECTIONS
,
Caution
Make sure power supply to unit is turned off.
NOTE: The electrician must refer to the nameplate and
wiring schematic on the refrigeration unit for correct
electrical requirements. All wiring must comply with all
safety codes. Make sure all refrigeration unit power switches
are in the OFF position.
1. Remove junction box cover.
2. Route and connect power supply to leads in the
electrical junction box at the top rear of the motor
compartment.
NOTE: Be sure to connect ground wire(s) to ground screw
located on back panel of junction box.
3. Replace junction box cover.
Tower Installation
1. Locate placement of tower on the countertop per
restaurant design. Verify counter has been prepared to
accept the tower via mounting holes. Refer to tower
specs for verification.
2. Mount tower with mounting hardware.