34
Part Number 020002365 08/25/2015
Operation
Section 3
PROGRAM MODE 1
To enter, press and hold switch for 3 seconds.
•
0001
will display indicating Mode 1
• Wait 3 seconds
C000
will display
• Press and hold
Carb A
switch — Display will indicate
one of the following:
ū
CA00
— Low and High Probes are open
(carbonator motor is energized)
ū
CA11
— Low and High Probes are closed
(carbonator motor is de-energized)
ū
CA01
— Low Probe closed (Motor will still be on)
• Press and hold
Carb B
switch — Display will indicate
one of the following:
ū
Cb00
— Low and High Probes are open
(carbonator motor is energized)
ū
Cb11
— Low and High Probes are closed
(carbonator motor is de-energized)
ū
Cb01
— Low Probe closed (Motor will still be on)
• Press and hold
COMP/AGIT
switch — Display will
indicate one of the following:
ū
CL 0
— Water level low
ū
CL 1
— Water level OK
• Press
PGM
Switch 1 time —
F000
will display:
ū
Press
COMP/AGIT
to toggle between
F000
(Fahrenheit) and
FC00
(Centigrade)
ū
Press and hold
Carb A
switch — Display will
indicate
Water Bath Temperature
ū
Press and hold
Circ A
switch — Display will
indicate
Liquid Line Temperature
ū
Press and hold
Circ B
switch — Display will
indicate
Suction Temperature
• Press
PGM
Switch twice or a second time —
P000
will
display
ū
Press and hold
Carb A
switch — Display will
indicate
Water Pressure
PROGRAM MODE 2
Add circulation pumps C and/or D.
• Press
PGM
button for 3 seconds - Display shows
0001
.
• Press
PGM
button again in less than 3 seconds - Display
shows
0002
program mode 2.
• Wait 3 seconds - Display shows
-002
= Factory default
setting.
ū
Pressing
CIRC A
button energizes/de-energizes
pump A
ū
Pressing
CIRC B
button energizes/de-energizes
pump B
• Program CIRC C - Press
CARB A
button - Display shows
-102 = Carb A
button energizes/de-energizes pump C
• Program CIRC D - Press
CARB B
button - Display shows
-012 = Carb B
button energizes/de-energizes pump D
• Four pumps shows
-112
.
NOTE: CIRC C motor needs to be connected to CARB A
output connection on the ERC board & CIRC D motor to
CARB B output connection.
Press and hold
PGM
switch for 3 seconds to save settings
and exit program mode.
PROGRAM MODE 3
This mode is for Beermaster units only and not used on
Soda or Water refrigeration systems. To turn this mode
ON/
OFF
do the following;
• Press
PGM
button for 3 seconds - Display shows
0001
.
• Press
PGM
button twice in less than 3 seconds to enter
program mode 3 - Display shows
0003
• Wait 3 seconds, display shows
-003
• Press the
COMP/AGIT
button once to toggle to BEER
MODE.
ū
BEER MODE ON
= Display shows
1273
ū
BEER MODE OFF
= Display shows
1- -3
,
Caution
If BEER MODE is ON, the water bath will be set to 27°F
factory default temperature setpoint and freeze. Do not
place Soda or Water refrigeration units in BEER MODE.
• Press and hold
PGM
switch for 3 seconds to save
settings and exit program mode.