TABLE 2(I) TR12 2-SPEED PROGRAMMING DIAGRAM.
STANDARD 2-SPEED 3, 4 & 5 MOTOR SYSTEM using SELECT
MOTOR 1 CONNECTIONS
MOTOR 2 CONNECTIONS MOTOR
3 CONNECTIONS
J4-3 MAIN
HOIST
UP
J3-3
TROLLEY
DIR 1
J2-3
BRIDGE
DIR 1
J4-2 MAIN
HOIST
2
ND
SPEED
J3-2
TROLLEY
2
ND
SPEED
J2-2
BRIDGE
2
ND
SPEED
J4-1 MAIN
HOIST
DOWN
J3-1
TROLLEY
DIR 2
J2-1
BRIDGE
DIR 2
J4-4 HOT (J4-1, 2 & 3)
J3-4 HOT (J3-1, 2 & 3)
J2-4 HOT (J2-1, 2 & 3)
INDEPENDENT CONNECTIONS
J5-2 SELECT 2
J5-1 HOT SELECT 2
J5-4 SELECT 1
J5-3 HOT SELECT 1
J5-6 AUX 3 ALARM
J5-5 HOT AUX 3 ALARM
TRANSMITTER SWITCH SETTINGS (This configuration does not apply to the Membrane transmitter).
telePilot
USE PDA SCREEN (Program the configuration switches 5, 6 and 7 to OFF. Under “Main/Aux” select the
word “Select”).
PENDANT, JLTX AND SLTX TRANSMITTER SWITCH SW4 “D” SETTINGS:
Position-1 Position-2 Position-5
Position -6
Position –7
ON ON OFF OFF OFF
*NOTE: Hoist, Trolley and Bridge are listed here as traditional configurations, the installer may choose to define the
motors differently.
Additional programming available:
The select function can be inverted by turning switch position 4 to ON (the Configuration Switch on the
tele
Pilot
or SW4
“D” for the Pendant, JLTX and SLTX).
Tandem select operation, both select 1 and 2 on at the same time, can be disabled by un-checking the box marked
“Tandem” on the
tele
Pilot
or turning on the Configuration Switch SW 4 “D” for the Pendant, JLTX and SLTX.
OFF
1 2 3 4 5 6 7 8
ON
For these switch
positions see
previous section.
Indicates Switch in OFF Position.
OUTPUTS
J2-3
J2-2
J2-1
BRIDGE*
MOTOR 3
1
ST
2
ND
Dir 1 Dir 2
OUTPUTS
J4-3
J4-2
J4-1
MAIN HOIST*
MOTOR 1
1
ST
2
ND
UP DN
2
ND
1
ST
2
ND
1
ST
OUTPUTS
J3-3
J3-2
J3-1
TROLLEY*
MOTOR 2
1
ST
2
ND
Dir 1 Dir 2
2
ND
1
ST
J5-2
J5-4
J5-6
SELECT 2
SELECT 1
AUX 3 ALARM
INDEPENDENT OUTPUTS