Section 7 – Programming (Continued)
66
7-7.
Pendant Transmitter Programming.
The Single-Speed or the 2-Speed 10K12 Pendant
Transmitter may be used with the TR12 Receiver. The
Pendant Transmitter M/C Board is shown in Figure 8-6. Refer to paragraphs below for programming
details Procedures.
7-7.1.
Pendant Transmitter Switch Settings.
SW3
Position Controls
1-3. Switch Positioning. (2-Speed only).
4-7. No function, keep off.
8.
Time-out-timer disable, turn “ON” to disable time-out-timer.
SW4
Position Controls
1-2 Mode Select. (Single-Speed Only).
3.
Disable Tandem Hoist. (2-Speed only).
4.
Invert Crane Select. (2-Speed only).
5-7. Special Crane Configurations. (2-Speed only).
8.
No function, keep OFF.
7-7.2.
Transmitter Switches SW3 And SW4 Programming. (See Section 8-2. Pendant Transmitter
Servicing for physical location of transmitter switches).
7-7.3.
Transmitter programming SW3
7-7.4.
Positions 1-3 Switch Positioning, 2-Speed Only. (Standard configuration all “OFF”).
The fun
c
tional positions of the various buttons controlling the hoist trolley and bridge can be moved by
transmitter dip switch SW3 also. Positions SW3-1 through SW3-3 control these functions. No change in
receiver wiring is needed to use these functions. See Section 7-7.13. for switch verses button
configurations.
7-7.5.
Position 4-7 No Function. (Keep turned “OFF”).
7-7.6.
Position 8 Time-out-timer Disable. (Normally keep turned “OFF”).
The transmitter has an approximate 15-minute time-out-timer. If the transmitter is not used for over 15
minutes it will shut down. This transmitter time-out-timer function is transmitter dip switch selectable.
SW3 position 8 disables the time-out-timer. Turning SW3-8 “ON” disables the time-out-timer.
7-7.7.
Transmitter Programming SW4
7-7.8.
Position 1-2 Mode Enable. (Standard Mode 1 keep 1-2 turned “OFF”).
Mode 1, SW4 1-2 all “OFF”. The 10K12 single-speed system comes standard configured this way from the
factory with three motion controls and six auxiliaries (controlled by the toggle switches). The 10K12 2-
speed system comes standard configured this way from the factory with three 2-speed controls and three
auxiliaries (controlled by the toggle switches, the rotary is non-functional).
Mode 2, SW4 1 turned “OFF” and SW4 2 turned “ON”. The 10K12 2-speed system configured this way is
able to control four 2-speed motion controls and no auxiliaries this give bridge, trolley, main and aux hoist.
The rotary selector switch functions are H1 main hoist, H2 aux hoist and B both main and aux hoist (the
toggle switches are non-functional).