Section 8 – RCP Programming (Continued)
97
See Section 7-3. Multibox for details on Multibox programming. If your current receiver does not have Multibox, do not
attempt to use this function. This function WILL NOT turn Multibox on in the receiver; it only assists you in programming
the correct transmitter access code for a receiver that already has Multibox. Make sure when you are using the Multibox
feature that the access code of the receiver is programmed into the access code above and not one copied from an existing
transmitter on a Multibox system. If you cannot find the receiver transmitter code and wish to copy an existing transmitter
on a Multibox system, put the transmitter’s access code in the access code switches above and DO NOT check the
Multibox box on the RCP screen.
Select the Tx #: this should be the next number in the series of transmitters being put on a Multibox system. If the are two
transmitters on already and you are adding a third, select the number 3. Make sure as stated in the Multibox section the
receiver is programmed for the appropriate number of transmitters.
The Tx # goes up to 8. Many Multibox systems only go to four. Check with your Telemotive representative if you need
more than 4 transmitters on a Multibox system.
Set Time-Out–Timer Time. Default time is 15 minutes.
The time it takes the transmitter to shut off due to lack of use is programmable. Click the pull down next to the word
“Timer” to program and scroll through the numbers shown. Units shown are in minutes.
Active ESTOP.
This feature causes the Receiver to shut down if the transmitter is out of range. For this to work the companion receiver
must have this feature also. Please check the receiver manual. All InteleSmart receivers have this feature; both the receiver
and the transmitter must have this box checked. DO NOT use this feature with non-equipped receivers. It is not
recommended to have multiple transmitters on the same channel if Active ESTOP is used due to the additional channel
loading.
Auto Turn Off. (Normally Leave Checked).
Auto Turn Off causes the unit to send an OFF command to the receiver if the battery goes bad or the transmitter times out.
Removing the check from this box disables this feature.
Repositioning of telePilot Transmitter Motion Switch Functions. (Standard configuration H, T, B).
The functional positions of the switches controlling hoist (H), trolley (T), and bridge (B) can be changed using the button
order pull down menu. This reconfiguration does NOT affect receiver wiring. As these switches are changed the motor
controls are moved.
Time-out-timer Disable. (Normally not checked).
Disables the transmitter time-out-timer if checked. If the time-out-timer is active, the length of time for time out can be
selected for numbers of minutes till shut down. The minutes are selectable in one-minute steps from 1 to 10 and five
minutes steps up to an hour. Scroll down through the number of minutes and click the desired number.
Tandem for Hoist, Trolley or Bridge. (Normally checked) 2 speed only.
This function appears if a four motor system or select function is chosen. Normally the box is checked, meaning “Both A
and B” operation is enabled (both MAIN and Aux or Select 2 and Select 1 can be ON at the same time). Removing the