8-1 Access Codes.
The access code is set at the factory and should not be changed unless absolutely necessary. If you are reprogramming a
spare or new transmitter make sure the other transmitter is securely taken out of service.
WARNING
TWO OPERATIONAL TRANSMITTERS WITH THE SAME ACCESS CODES OPERATING AT THE SAME TIME
IS A DEFINITE SAFETY HAZARD. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS
INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
Figure 8-1. Access Code Setting.
(A dot on a switch position or a “1” in the
label is an indication that the respective
switch position should be ON).
Sample Membrane or
Pendant
Transmitter
Access Code Label
Sample access code only; do not use
SW1
OFF
1 A
8
ON
OFF
ON
8 B 1
MODEL # -10KXXXXXXXX
S/N=XXXXXXXXXXXXXXXXX
ACCESS CODE SETTING
1 A 8 1 B 8
0 1 0 0 0 1 1 1 0 1 1 0 0 0 1 0
FREQ : = AK01 J # = XXXXX
Access Code Switches
Sample access code only, do not use
SW2
ON
ON
SW1
8 A 1
OFF
OFF
8 B 1
TR12 Receiver
ON
8 A 1
SW2
OFF
8 A 1
1 B 8
OFF
ON
SW2
OFF
A1
telePilot
Transmitter
1 A 8
ON
OFF
1 B 8
ON
OFF
B1
Receiver access code
1
0
1
0
Indicates switch in OFF position