5-39
Continued
n011 :
Frequency – Max. (Fmax)
n012 :
Voltage – Max. (Vmax)
n013 :
Frequency – Max. Voltage point (F
A
)
n014 :
Frequency – Midpoint (F
B
)
n015 :
Voltage – Midpoint (V
C
)
n016 :
Frequency – Min. (Fmin)
n017 :
Voltage – Min. (Vmin)
These seven parameters define the V/f pattern. The illustration below shows how these constants
relate to each other in establishing the custom V/f pattern.
NOTE: To establish a V/f pattern with a straight line from Fmin to F
A
, set
F
B
= Fmin. The setting of V
C
is then disregarded and does not affect the
V/f pattern.
IMPORTANT
The V/f parameter settings are checked each time the ENTER key is
pressed while programming the V/f parameters. A parameter set value
failure (Err ) will occur if any part of the following relationships among
n011
thru n017 is not TRUE:
(a)
Fmax
≥
F
A
≥
F
B
≥
Fmin
(b)
Vmax
≥
V
C
≥
Vmin
5.27 V/f PATTERN
V/f Characteristics Set by n011 thru n017
Vmax
(
n012
)
OUTPUT
VOLTAGE
V
C
(
n015
)
Vmin
(
n017
)
Fmin
F
B
F
A
Fmax
(
n016
)
(
n014
)
(
n013
)
(
n011
)
OUTPUT FREQUENCY