background image

P5-20...R40-17

Model: E16-V1

en

Assembly and Operating Instructions

Sun protection drives with locking system

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 301 019 0a     22/01/2018   

Summary of Contents for E16-V1

Page 1: ...drives with locking system Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 301 019 0a 22 01 2018 ...

Page 2: ...Assembling and disassembling the drive adapter with separate drive adapter safety catch 10 Assembling and disassembling the drive adapter with screw connection 10 Mounting the drive in the tube 10 Setting the limit positions using the programming unit 12 Deleting the limit positions using the programming unit 13 Adjusting the limit positions with a rotary switch or a locking button 14 Deleting the...

Page 3: ...r and the numbers 3 and 4 indicate the calendar week Example 24th calendar week in 2012 Ser No 1224XXXXX Explanation of pictograms CAUTION CAUTION indicates a hazardous situation which if not avoided could result in injury ATTENTION ATTENTION indicates measures that must be taken to avoid damage to property Denotes user tips and other useful information Warranty Structural modifications and incorr...

Page 4: ...of safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the drive manufacturer If any questions or uncertainties rega...

Page 5: ...s e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technical reasons Before installation shut down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or...

Page 6: ...not suitable for transporting the drive Always carry the drive by the housing tube Other applications uses and modifications are not permitted in order to protect the safety of the users and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such act...

Page 7: ...wer supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 35 A A snap in pin 7 ...

Page 8: ...wer supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 45 and dia 58 1 2 A A locating latch 8 ...

Page 9: ...sponsible electrical contractor Calculate the space required at the side M by measuring the drive head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the ba...

Page 10: ...pter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Mounting the drive in the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These groove recesses have different sizes and allow the drive to fit ex...

Page 11: ...elf tapping screw dia 6 3 x 13 mm We also recommend screwing the idler to the barrel Attention Do not hammer the tubular drive into the tube or drop it into the barrel Assemble the tubular drive with the relevant ring 1 and drive adapter 2 If the ring has several grooves select the groove which is a perfect fit and push the ring 1 onto the thrust ring Insert the tubular drive with the pre assemble...

Page 12: ...ommissioning long drop distance or long running time the thermoswitch may trigger The drive will switch off After a short cooling down period the system is ready for operation again The drive does not achieve its full duty cycle until it has cooled to ambient temperature Avoid a situation where the thermal protection switch cuts in repeatedly If the tubular drive switches off prematurely while ope...

Page 13: ...and open it Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply Please pause for 1 sec after the last drive command before beginning the deletion se quence Also leave a pause of 1 sec between the individual steps of the deletion sequence black brown blue green yellow black ...

Page 14: ...nts overheating of the tubu lar drive During commissioning long drop distance or long running time the ther moswitch may trigger The drive will switch off After a short cooling down period the sys tem is ready for operation again The drive does not achieve its full duty cycle until it has cooled to ambient temperature Avoid a situation where the thermal protection switch cuts in repeatedly If the ...

Page 15: ...cking limit position is now saved and the tubular drive makes a click sound to confirm 1 s 1 s until STOP and hold until Limit positioning is now complete The sun protection system will now lock and unlock automatically in the lower limit position when you close and open it Deleting the limit positions with a rotary switch or a locking button The functions and presettings of the model versions are...

Page 16: ...seconds The drive moves a short distance out of the limit position and back again The fabric untensioning function is now active Repeat the procedure to deactivate it Information for the electrician Tubular drives with electronic limit switching can be connected in parallel The maximum switching contact load of the switching equipment timer relay control switch etc must be observed To operate driv...

Page 17: ...nsioning Adjusting and deleting the limit positions with a rotary switch or a lock ing button present activated on delivery deactivated on delivery not present Technical data dia 35 Tubular drive P5 20 P9 16 Model E16 V1 Type C SEO I3 Rated torque Nm 5 9 Output speed rpm 20 16 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 115 110 Rated current consumption A 0 47 ...

Page 18: ...ons Due to long cable L1 and N connection have been reversed Change around L1 and N N blue L1 black brown reset limit positions Repair system delete limit positions then re program limit po sitions Tubular drive stops arbitrarily cannot be restarted in the same direction Use a more powerful tubular drive Ensure that the sun protection system runs smoothly Delete limit positions then re program lim...

Page 19: ...lack and brown wires according to the direction of travel is de pendant on how the drive is installed mounted to the right or to the left Controlling one several drive s via a single switch button Controls black brown blue green yellow Controls 19 ...

Page 20: ...Declaration of conformity 20 ...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ......

Reviews: