background image

XR7/85

Version: CM 4A

en

Assembly and Operating Instructions

Tubular drive with mechanical limit switching for fly

screen systems

Important information for:

• Fitters / • Electricians / • Users

Please forward accordingly!

These instructions must be kept safe for future reference.

Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

2010 300 701 0     30/07/2019   

Summary of Contents for Extended Features XR7/85

Page 1: ...imit switching for fly screen systems Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 701 0 30 07 2019 ...

Page 2: ...cting cable for tubular drives dia 45 and dia 58 7 Installation 8 Assembling the drive 8 Undoing the mounting pin 8 Assembling the drive adapter with screw connection 8 Securing the drive against axial displacement 9 Fixing the drive adapter to the barrel dia 45 9 Mounting the drive in the tube 9 Setting the limit positions 11 Information for the electrician 12 Disposal 12 Maintenance 12 Technical...

Page 3: ...t must be taken to avoid damage to property Denotes user tips and other useful information Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries e g crushing of limbs Therefore structural modifications may only be carried out with our prior approval and strictly in accordance with our instructio...

Page 4: ...of safety instructions is not exhaustive since it would be impossible for the standard to include all sources of danger For example the design of the operated product the way the drive works in the situation it is installed in or even the way the end product is mounted in the end user s place of use cannot be taken into consideration by the drive manufacturer If any questions or uncertainties rega...

Page 5: ...s e g the power supply unit are live Physical injuries or damage to property can result in the event of unauthorised interventions or failure to heed warnings Be careful when touching the tubular drive as it heats up during operation for technical reasons Before installation shut down all lines and control devices that are not essential for op eration Crushing or shearing points must be avoided or...

Page 6: ... carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from improper usage Assembling and disassembling the plug in connecting cab...

Page 7: ...wer supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 45 and dia 58 1 2 A A locating latch 7 ...

Page 8: ... M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al lowed for the mounted system Attention When using rigid shaft connectors closed brackets must be fitted The tubular drive presses the closed curtain down to make i...

Page 9: ...to fit exactly For round tubes First notch the tube on the motor side so the lug of the thrust ring can also be pushed into the tube There must be no play between the lug of the thrust ring and the tube For rings without drive lugs which are used to assist fitting on the thrust ring the bar rel must be connected to the thrust ring by a 4 8 x 9 5 mm self tapping screw Assemble the tubular drive wit...

Page 10: ...ntinuous operation and has only been designed for start up Lay the connecting cable Lay the connecting cable up to the tubular drive and fix The connecting cable and any antennae must not project into the winding chamber Cover any sharp edges 10 ...

Page 11: ...by turning the corresponding set screw Test for proper functioning As a final check run the shading solution to the limit positions in both directions again Attention The tubular drives are designed for short time operation for the operating mode please see technical data An inbuilt thermal protection switch prevents overheating of the tubu lar drive During commissioning long drop distance or long...

Page 12: ...be at least 0 5 s The switch and control must not execute simultaneous UP and DOWN com mands Protect the electrical connections from damp Once you have finished wiring everything to the control ALWAYS check the right direction assignment of the drive to the control buttons UP and DOWN EXTEND and RETRACT If the drive is to be operated with devices which contain sources of interference the elec tric...

Page 13: ...the same direction Roller shutter curtain keeps sticking too much friction Repair system Tubular drive does not run in the right dir ection Electrical connection faulty Check the electrical connection Sample wiring diagrams Control via a single switch button black brown blue green yellow 13 ...

Page 14: ...dual control using Centronic UnitControl UC42 Mains 230 V 50 Hz Central Group Individual Individual 230 V 50 Hz Central cable connection to further control units 230 V 50 Hz 230 V 50 Hz Electronics 230 V 50 Hz Control unit 14 ...

Page 15: ...Declaration of conformity 15 ...

Page 16: ......