![background image](http://html1.mh-extra.com/html/magnetek/gpd-315/gpd-315_technical-manual_3602605099.webp)
A3-1
The factory setting of certain parameters change with drive rating and control method selected. The
following two tables list the parameters and how they change.
Appendix 3. CAPACITY & CONTROL METHOD
RELATED PARAMETERS
GPD 315
Model
n036
n105
n106
n107
n108
n110
MVA001
0.6
1.7
2.5
17.99
110.4
72
MVA002
1.1
3.4
2.6
10.28
56.08
73
MVA003
1.9
4.2
2.9
4.573
42.21
62
MVA005
3.3
6.5
2.5
2.575
19.07
55
MVA008
6.2
11.1
2.6
1.233
13.40
45
MVA011
8.5
11.8
2.9
0.800
9.81
35
MVA017
14.1
19.0
3.3
0.385
6.34
32
MVA025
19.6
28.8
1.5
0.199
4.22
26
MVA033
26.6
43.9
1.3
0.111
2.65
30
MVB001
0.6
3.4
2.5
41.97
224.3
73
MVB002
1.0
4.0
2.7
19.08
168.8
63
MVB003
1.6
6.1
2.6
11.22
80.76
52
MVB005
3.1
11.0
2.5
5.044
53.25
45
MVB006
4.2
11.7
3.0
3.244
40.03
35
MVB009
7.0
19.3
3.2
1.514
24.84
33
MVB015
9.8
28.8
1.5
0.797
16.87
26
MVB018
13.3
43.9
1.3
0.443
10.59
30
Table A3-1. Parameters Related to GPD 315 Capacity
V/f Control Mode
Open Loop Vector
Parameter
Description
(n002 = 0)
(n002 = 1)
n014
Frequency - Midpoint
1.5
3.0
n015
Voltage - Midpoint
12.0 (230)
11.0 (230)
24.0 (460)
22.0 (460)
n016
Frequency - Min.
1.5
1.0
n017
Voltage - Min.
12.0 (230)
4.3 (230)
24.0 (460)
8.6 (460)
n104
Torque Compensation Time
0.3
0.2
n111
Slip Compensation Gain
0.0
1.0
n112
Slip Compensation Time
2.0
0.2
Table A3-2. Parameters Related to Control Method