TO ADJUST THE GATE SETTINGS
From the screen:
1. Click on the Gate button in the lower
menu bar. The GATE control panel ap-
pears on the screen.
2. The first control in the GATE window
adjusts the gate threshold, with a
range from –60.00 dB to –1.00 dB.
Click and drag up on the control to in-
crease the threshold and drag down to
decrease the threshold.
3. The second control adjusts the gate at-
tack time, with a range from 0.10 ms
(milliseconds) to 599.99 ms (0.6 sec-
onds). Click and drag up on the control
to increase the attack time and drag
down to decrease the attack time.
4. The third control adjusts the gate re-
lease time, with a range from 10.00 ms
to 2500.00 ms (2.5 seconds). Click
and drag up on the control to increase
the release time and drag down to de-
crease the release time.
5. The fourth control adjusts the range of
the compressor, with a range from
0.00 dB to 100.00 dB. Typically, you
would leave this set to maximum ex-
pansion. Click and drag up on the
control to increase the range and drag
down to decrease the range.
Summary of Contents for 8-BUS Series
Page 49: ...3 16 D i g i t a l 8 B u s Start Up ...
Page 57: ...4 8 D i g i t a l 8 B u s Connections ...
Page 77: ...5 20 D i g i t a l 8 B u s Preparing for a Session ...
Page 177: ...7 20 D i g i t a l 8 B u s Automation ...
Page 207: ...D 2 D i g i t a l 8 B u s Apogee UV22 ...
Page 219: ...F 4 D i g i t a l 8 B u s Optional I O Cards ...
Page 227: ...H 2 D i g i t a l 8 B u s Upgrading ...
Page 235: ...K 2 D i g i t a l 8 B u s ...
Page 237: ...D i g i t a l 8 B u s ...
Page 239: ...D i g i t a l 8 B u s ...