215634
93
Revision B
3.16
Connecting Signal Light Placards and Registration Plate Electrical
Harness
Follow these steps to connect the signal light placards and registration plate mount electrical harness.
1034354
A
B
B
C
D
E
Figure 3.107: Electrical Harness Routing
The narrow transport lighting leg harness (A) is routed next to
the wheel legs and connects to the signal light placards (B) on
the cab side and to the narrow transport main harness (C). The
narrow transport main harness (C) connects to the registration
plate mount (E) just below the cab, and is routed to the walking
beam to connect to the signal light placards (D).
Cab-forward signal light placards harness
1034458
A
B
C
Figure 3.108: Left Cab-Forward Signal Light Placard
1.
Route left lighting leg harness (A) behind left signal light
placard (B) mounting plate as shown.
2.
Loosely secure harness to placard lighting bracket with a
cable tie (C).
1034459
A
B
C
D
E
F
Figure 3.109: Left Cab-Forward Signal Light Placard
3.
Insert the harness down the plate hole.
4.
Connect the lighting leg harness to the left signal light
placard as follows:
a.
Plug P295S (A) to side turn signal receptacle.
b.
Plug P295 (B) to A side receptacle.
c.
Plug P267B (C) to B side receptacle.
d.
Plug P267A (D) to A side receptacle.
5.
Secure harness with fir tree fasteners (E), and tighten cable
tie (F).