Symptom
Problem
Solution
Section
Low battery output
Check battery charge.
Loose or corroded battery
connections
Clean and tighten loose connections.
Move GSL to NEUTRAL.
4.3.6 Windrower
Operation, page
94
Move steering wheel to CENTER
position.
Controls not in NEUTRAL
Disengage header.
Engaging and
Disengaging the
Header, page 124
Relay not functioning
Check relay and wire connections.
Main fuse defective/blown
Replace main fuse.
Key power fuse blown
Replace.
5.7.8 Electrical
System, page 259
Key switch worn or terminals
loose
Contact Dealer.
Switch at Interlock not closed
or defective
Adjust switch or replace. Contact your
Dealer.
Contact Dealer.
Starter cranks
slowly or will not
operate
Crankcase oil too high
viscosity
Use recommended oil.
Lubricants, Fluids,
and System
Capacities, page
199
Air
fi
lters require
frequent cleaning
Aspirator plugged
Clean out aspirator.
169890
322
Revision A
Summary of Contents for M105
Page 8: ......
Page 28: ...SAFETY Figure 1 21 Safety Signs LH Side 169890 14 Revision A ...
Page 30: ...SAFETY Figure 1 23 Safety Signs RH Side 169890 16 Revision A ...
Page 40: ......
Page 87: ...OPERATOR S STATION 169890 73 Revision A ...
Page 88: ...OPERATOR S STATION 169890 74 Revision A ...
Page 89: ...OPERATOR S STATION 169890 75 Revision A ...
Page 90: ...OPERATOR S STATION 169890 76 Revision A ...
Page 91: ...OPERATOR S STATION 169890 77 Revision A ...
Page 92: ...OPERATOR S STATION Operating Information Screens 169890 78 Revision A ...
Page 94: ......
Page 299: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 169 Fuse Decal 169890 285 Revision A ...
Page 350: ......
Page 372: ......
Page 382: ......
Page 383: ......