1. Insert new primary
fi
lter element (A) into canister over
secondary element, and push into place, ensuring that
element is
fi
rmly seated in canister.
Figure 5.72: Engine Air Cleaner
2. Align arrow (A) to UNLOCK position on end cap, and
push end cap fully onto housing.
3. Rotate end cap clockwise until catch (A) engages
housing to prevent end cap from turning.
Figure 5.73: Engine Air Cleaner
4. Position end cap (B) onto
fi
lter housing with aspirator
pointing approximately down.
5. Secure end cap onto
fi
lter housing by closing latch (A).
Figure 5.74: Engine Air Cleaner