Preventing Electrical System Damage
To prevent electrical system damage, take the following
precautions:
• Carefully
observe
polarity
when
attaching
booster battery.
• Do
NOT
short across battery or alternator terminals,
or allow battery positive (+) cable or alternator wire to
become grounded.
• Be sure alternator connections are correct before cables
are connected to battery.
• When welding on any part of the machine, disconnect
battery cables and alternator wire. Refer to
• Always disconnect battery ground cable when working
with the alternator or regulator.
• Never attempt to polarize alternator or regulator.
• If wires are disconnected from the alternator, use the
illustration to ensure proper reconnection.
• Never ground the alternator
fi
eld terminal or
fi
eld.
• Never connect or disconnect alternator or regulator
wires with battery connected or alternator operating.
• Always disconnect cables from the battery when using
a charger to charge battery in windrower.
• Ensure all cables are securely connected before
operating engine.
Figure 5.120: Alternator
A - Negative Terminal
B - Positive Terminal
Maintaining Batteries
CAUTION
Do NOT attempt to service battery unless you have the proper equipment and experience to perform the
job. Have it done by a qualified Dealer.
• Check battery charge
once a year
, and more often if operating in cold weather. Hydrometer readings should be
1.260 to 1.300. Readings below 1.250 indicate charging is required. Refer to
Charging the Battery, page 262
.
Add electrolyte if necessary. Refer to
Adding Electrolyte to the Battery, page 265
.
• Keep batteries clean by wiping with a damp cloth.
• Keep all connections clean and tight. Remove any corrosion, and wash terminals with a solution of baking soda
and water. A light coating of grease on terminals (after cables are attached) will reduce corrosion.
• To prolong battery life, store batteries fully charged and at +20° to +80°F (-7° to +26°C). Check voltage after
storage, and recharge as needed, according to battery and charger manufacturer recommendations.
• Do
NOT
stack storage batteries on top of each other.
169890
260
Revision A
Summary of Contents for M105
Page 8: ......
Page 28: ...SAFETY Figure 1 21 Safety Signs LH Side 169890 14 Revision A ...
Page 30: ...SAFETY Figure 1 23 Safety Signs RH Side 169890 16 Revision A ...
Page 40: ......
Page 87: ...OPERATOR S STATION 169890 73 Revision A ...
Page 88: ...OPERATOR S STATION 169890 74 Revision A ...
Page 89: ...OPERATOR S STATION 169890 75 Revision A ...
Page 90: ...OPERATOR S STATION 169890 76 Revision A ...
Page 91: ...OPERATOR S STATION 169890 77 Revision A ...
Page 92: ...OPERATOR S STATION Operating Information Screens 169890 78 Revision A ...
Page 94: ......
Page 299: ...MAINTENANCE AND SERVICING Fuse Box Decal Figure 5 169 Fuse Decal 169890 285 Revision A ...
Page 350: ......
Page 372: ......
Page 382: ......
Page 383: ......