3.6.3
Installing Hydraulics on an M105
1.
Locate two hoses (MD #111324 [green ties]) (A) in
frame opening and existing tee fitting (green tie) on the
hose from the valve block.
2.
Remove one cap from tee fitting, and quickly attach
hose (A) to minimize oil spillage.
3.
Remove second cap from tee fitting, and quickly
connect other hose (A).
4.
Tighten fittings.
5.
Position hoses into frame.
Figure 3.60: Hose Routing
6.
Locate two hoses (white ties) inside frame and
hose (MD #111324) with existing tee fitting (white
tie) (A).
7.
Remove caps, make connections, and tighten fittings.
8.
Position hoses into frame.
Figure 3.61: Hose Routing
9.
Locate two hoses (red ties) (A) inside frame.
10. Route right-hand hose behind bundle.
11. Remove caps, make connection, and tighten fitting.
12. Position hoses into frame.
Figure 3.62: Hose Routing
147962
53
Revision A