4.
Press left (B) or right (C) arrows to select knife speed.
Press SELECT (D).
5.
Press PROGRAM (A) to exit Programming Mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Figure 4.84: M155 Knife Speed
Figure 4.85: M205 Knife Speed
4.4.6
Setting the Knife Overload Speed
NOTE:
• The header
MUST
be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header.
• The recommended knife overload speed is 75% of knife speed. For more information, refer to
and Adjusting Knife Speed, page 351
to determine proper overload speed.
• Displaying knife drive speed on cab display module (CDM) requires installation of the optional Expansion Module
(MD #B4666). For more information, refer to the windrower operator’s manual or the windrower technical manual.
147962
190