CAUTION
Check to be sure all bystanders have cleared the area.
6.
Press and hold the HEADER UP (C) button on the
ground speed lever (GSL).
• CALIBRATING
HEIGHT
is
displayed
on
the
upper line.
• RAISE HEADER HOLD is displayed on the
lower line.
NOTE:
The word HOLD will flash during calibration.
RAISE HEADER DONE will display on the lower
line once calibration is complete.
7.
Release the HEADER UP (C) button.
• HEIGHT SENSOR CAL is displayed on the
upper line.
• PRESS LOWER HEADER is displayed on the
lower line.
Figure 4.54: Header Height Controls on Ground
Speed Lever
8.
Press and hold HEADER DOWN (A) button on GSL.
NOTE:
The word HOLD will flash during calibration. HT
SENSOR COMPLETE will display on the lower
line once calibration is complete.
9.
Release HEADER DOWN (A) button.
• TO CALIBRATE SELECT is displayed on the
upper line.
• HEADER HEIGHT is displayed on the lower line.
10. Press right arrow to select next header sensor
calibration or STOP & EXIT. Press SELECT.
Refer to
4.3.2 Calibrating the Header Tilt Sensor, page
or
4.3.3 Calibrating the Header Float Sensors,
.
11. Press PROGRAM to exit Programming Mode.
Figure 4.55: Header Height Controls on Ground
Speed Lever
147962
175
Revision A