4.
Press SELECT (D) until DISK OVERLOAD SPD? is
displayed on the upper line.
• The current overload speed is displayed on the
lower line.
NOTE:
Default setting is -300 rpm. Range is -500 to
-100 rpm.
5.
Press left (B) or right (C) arrows to set disc overload
speed. Press SELECT (D).
6.
Press PROGRAM (A) to exit Programming Mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Figure 4.94: M155 Disc Overload Speed
Figure 4.95: M205 Disc Overload Speed
4.4.8
Setting the Hydraulic Overload Pressure
NOTE:
• This procedure requires installation of the optional pressure sensor (MD #B5574). For overload pressure values,
refer to pressure sensor installation instructions (MD #169031).
• To enable sensor, refer to
4.7.2 Switching the Installed Header Sensors ON or OFF, page 256
147962
194
Revision A