Instruction Manual MC6000
7-14
Ref. Value
IS01
Speed
0 to + 10 V
0
0 to + 3000 rpm
0 to + 10 V
1
0 to - 3000 rpm
Result:
Ref. Value
IS01
Speed
0 to + 10 V
0
+1000 to +3000 rpm
0 to + 10 V
1
+1000 to +3000 rpm
Ref value
Speed
0 to 10 V
-1000 to 3000 rpm
2.5 V
0 rpm
Note:
The Servocontroller parameter settings are factory-set so that the acceleration and deceleration
ramps (ACCR and DECR) are switched off and the matching factor RF3FA = 100 %.
The parameters of the drive are already set to meet the requirements of the operation. The
control circuits have been set to suit the motor by reading in the S
MART
C
ARD
and do not require
any further matching in standard applications.
c) Setting parameters for asymmetrical speed range
Solution 1: with prefix switching
A fixed reference value channel 1 is switched on which continuously adds 1000 min
-1
to the
reference value of the analog input. The following changes should be made:
RSSL1
= RFIX1
RFIX1
= 1000
RNA1
= 2000
Result:
Solution 2: without prefix switching
Using a fixed reference value 1000 min
-1
are continuously subtracted from the reference
value of the analog input. The following changes should be made:
RSSL1
= RFIX1
RFIX1
= -1000
RNA1
= 4000
FIS01
= OFF
Result: