Instruction Manual MC6000
10-35
PLRDY
Parameter List Ready
manual update of the parameter list and re-initialisation
Parameter number:
15
Physical unit:
-
Value range:
0, 1
Factory setting:
0
Customer setting:
Display level:
4
Editing level:
4
S
MART
C
ARD
area:
no data storage
Explanation:
The control can be initialised using this parameter. The paramter list is checked for validity and
the dependent paramaters are calculated (see section 6.7). Manual update of the parameter
list is started by setting the parameter PLRDY=1. The parameter is then reset automatically =0.
When the start command (controller enabled) is cancelled, re-initialisation of the control starts
immediately. In the subsequent controller enable, the new parameter values are active
immediately without delay.
_CONF
_ENCD
_OPT2
_OPT1
_MOT
_TCON
_SCON
_PCON
_SIO
_KPAD
_SCTY
_REF
PROG
Program Functions
Select special program functions
Parameter number:
4
Physical unit:
-
Value range:
see table below
Factory setting:
2
Customer setting:
Display level:
3
Editing level:
3
S
MART
C
ARD
area:
SYSTM
PNUM
Parameter Number
Switch parameter on/off
Parameter number:
6
Physical unit:
-
Value range:
OFF {0} / ON {1}
Factory setting:
OFF
Customer setting:
Display level:
4
Editing level:
4
S
MART
C
ARD
area:
SYSTM
Note:
When parameter number display is switched off the display indicates whether the parameter
can only be displayed or also edited (-S- or. -E-).
Setting
Function
1
Reset all parameters to factory setting
2
Normal setting no funtion
111
Re-initialisation of serial interface with the current
value of parameter SBAUD