Instruction Manual MC6000
10-46
STOPR
Stop Ramp
Stop ramp (for emergency stop)
Parameter number:
496
Physical unit:
min
-1
s
-1
Value range:
0 - 65536
Factory setting:
0
Customer setting:
Display level:
2
Editing level:
2
S
MART
C
ARD
area:
REFRC
SADD1, SADD2, SADD3, SADD4
Selector Addition Value for
Offset for reference value selectors 1 to 4 (RSSL1 -
RSSL1 - 4
RSSL4), Offset is entered via digital inputs. Parameters
only for the display of the current value.
Parameter number:
421, 422, 423, 424
Physical unit:
decimal
Value range:
0 - 15
Factory setting:
0
Customer setting:
Display level:
2
Editing level:
cannot be edited
S
MART
C
ARD
area:
ALL
RSSL1, RSSL2, RSSL3, RSSL4
Reference Source Selector 1 - 4
Reference value selectors for channels 1 to 4, used for
selecting a reference value source
Parameter number:
417, 418, 419, 420
Physical unit:
-
Value range:
see table below
Factory setting:
RCON, RSSL3= RFIX1
Customer setting:
Display level:
2
Editing level:
2
S
MART
C
ARD
area:
REFRC
No.
Setting
Reference value source
0
RCON
None (reference value source switched off [constant =0])
1
RA0
Analog input ISA0
2
RA1
Analog input ISA1
3
RSIO
Serial interface
4
RPOT
Motor operated potentiometer at digital inputs
5
RDIG
Digital reference value input (PWM)
6
ROPT1
Module in Slot 1 (X6)
7
ROPT2
Module in Slot 2 (X7)
8
RFIX1
Fixed reference value 1
9
RFIX2
Fixed reference value 2
10 RFIX3
Fixed reference value 3
11 RFIX4
Fixed reference value 4
12 RFIX5
Fixed reference value 5
13 RFIX6
Fixed reference value 6
14 RLIM1
Lower limit of reference value
15 RLIM2
Upper limit of reference value