![Lust MASTERCONTROL MC6000 Series Instruction Manual Download Page 151](http://html1.mh-extra.com/html/lust/mastercontrol-mc6000-series/mastercontrol-mc6000-series_instruction-manual_1950408151.webp)
Instruction Manual MC6000
11-2
Terminal Terminal
Description
No.
Allocation
1
IE00
Inputs
2
IE01
(Input External 00 - 07)
3
IE02
4
IE03
5
IE04
6
IE05
7
IE06
8
IE07
9
GND-IN
Ground for
inputs
10
GND
Ground for Servo
Terminal Terminal
Description
No.
Allocation
1
GND-OUT Ground for
outputs
2
+24V-OUT + 24 V supply
for outputs
3
OE00
Outputs
4
OE01
(Output External 00 - 03)
5
OE02
6
OE03
11.2
Terminal Allocation I/O Module1
Input terminals (X14)
Output terminals (X13)
+24V-OUT
+5V
GND-OUT
X13
2
1
X13
2
1
GND
+24V
+24V (X5)
1
2
OExx
GND
(X5 / X14)
+5V
GND-IN
GND
GND-IN
X14
9
10
X14
9
10
+24V (X5)
IExx
1
2
GND
IExx
+24V
Note:
The housing is at same potential as the cable
screening.
Sub D connector (X15)
The connector plug can be used for connecting the external EKL300 Terminal Module via a
screened 1:1 connector cable (KSS252) or for direct wiring of the installation.
1
2
3
4
5
6
7
8
10
11
12
13
9
14
15
16
17
18
20
21
22
23
19
24
25
IE00
IE02
IE04
IE06
GND-IN
GND
GND-OUT
OE00
OE02
24V-CAN
GND-CAN
GND-CAN
CAN+
n.c.
IE01
IE03
IE05
IE07
OE01
OE03
+24V
24V-OUT
n.c.
n.c.
CAN-
Versions for voltage supply
- potential-isolated, ex 24 V supply required
- not potential-isolated, using in 24 V from Servocontroller (200 mA)
via a bridge from control terminal X5
2
1