Instruction Manual MC6000
10-40
_CONF
_ENCD
_OPT2
_OPT1
_MOT
_TCON
_SCON
_PCON
_SIO
_KPAD
_SCTY
_REF
R-PLS
Reaction on Error Plausibility Check
Reaction to errors in plausibility check
Parameter number:
50
Value range:
3 - 5
Factory setting:
5
Customer setting:
R-OTI
Reaction on Error Over
Reaction to Servocontroller overtemperature
Temperature Inverter
Parameter number:
47
Value range:
1 - 5
Factory setting:
1
Customer setting:
R-PWR
Reaction on Error Power
Reaction to unrecognised power stage error
Parameter number:
53
Value range:
5
Factory setting:
5
Customer setting:
R-PAR
Reaction on Error Parameter List
Reaction to invalid data in parameter list
Parameter number:
51
Value range:
3 - 5
Factory setting:
3
Customer setting:
R-OV
Reaction on Error Over Voltage
Reaction to overvoltage error
Parameter number:
44
Value range:
1 - 5
Factory setting:
3
Customer setting:
R-OTM
Reaction on Error Over
Reaction to motor overtemperature
Temperature Motor
Parameter number:
46
Value range:
0 - 5
Factory setting:
1
Customer setting: