![Lust MASTERCONTROL MC6000 Series Instruction Manual Download Page 102](http://html1.mh-extra.com/html/lust/mastercontrol-mc6000-series/mastercontrol-mc6000-series_instruction-manual_1950408102.webp)
Instruction Manual MC6000
9-4
9.2.2
K
EY
P
AD
operator errors
The following operator errors may occur when using the KP100 K
EY
P
AD
:
1)
A higher operating level is only accessible to users familiar with the device and who have the
appropriate authorization including the password for access to the operating level.
Acknowledge error by pressing start/enter key.
9.2.3
Errors when using S
MART
C
ARD
These errors occur when illegal - and generally unintentional - operations are being carried out,
eg an attempt to write to a back-up copy of parameter data or use of a S
MART
C
ARD
to operate the
VF1000 range of inverters. The use of another S
MART
C
ARD
is recommended.
Acknowledge error by pressing stop/return key.
Error
Meaning
ERR91
SmartCard is write protected
ERR92
error in validity checking
ERR93
SmartCard not reading, incorrect servo or inverter type
ERR94
SmartCard not readable, parameters incompatible
ERR96
link to SmartCard distrupted
ERR97
SmartCard data invalid (CS test)
ERR98
insufficient memory on SmartCard
ERR99
selected area not on SmartCard, no parameters
transferred from SmartCard
Error
Cause
Solution
ATT1
parameter cannot be changed in current
select higher MODE 1)
level mode or cannot be edited
ATT2
motor must not be controlled on-line from
cancel start signal from
the CTRL menu
another control location
ATT3
motor must not be controlled from CTRL
reset error
menu because of error condition
ATT4
new parameter value illegal
change value of parameter
ATT5
new parameter value too high
select lower parameter value
ATT6
new parameter too small
select higher parameter value
ATT7
card must not be read in its present
stop control (cancel start signal)
condition
ATT8
permissible speed limit value for SCSMX
Reduce SCSMX (_SCON) to
too high for selected control type or motor
permissible values
ATT9
CTRL menu cannot be used with PosMod1
select different menu or
remove PosMod1
ERROR
invalid password
enter correct password for
operating level 1)