![Lust MASTERCONTROL MC6000 Series Instruction Manual Download Page 107](http://html1.mh-extra.com/html/lust/mastercontrol-mc6000-series/mastercontrol-mc6000-series_instruction-manual_1950408107.webp)
Instruction Manual MC6000
10-4
No. Name
MODE Unit
Title
Description
75
CURNT
1
A
Current
Instantaneous effective output current
76
TORQE
1
Nm
Torque
Instantaneous torque
77
SPEED
1
rpm
Speed
Speed instantaneous rpm
78
POS
1
U
Position
Instantaneous position
86
TSYS
1
min
System Time
System time (time since switch-on)
87
TOP
1
h
Time of Operation Time of operation
90
SREV
1
Standard Revision A reference to standard software in
customer software
91
TYPE
1
Type
Type of equipment
92
REV
1
Revision
Software version
94
TERR
1
min
Time Error
Time between switch-on and the last
error
95
ERR1
1
Error 1
Last error 1)
339 OP1RV
1
Option 1 Revision Software version of Module in slot X6
(if present)
340 OP2RV
1
Option 2 Revision Software version of Module in slot X7
(if present)
347 DCV
1
V
DC (Link) Voltage DC link voltage
400 ACTV
1
Nm, rpm, U
Actual Value
Actual value of control value
427 TEMP
1
°C
Temperature
Temperature des MC6000
447 REFV
1
Nm, rpm, U
Reference Value
Reference value of control value
495 IOSTA
1
I/O Status
Status of inputs and outputs 2)
9
TAX
3
%
Controller Tax
Instantaneous load on controller
10
MAXTX
3
%
Maximum Tax
Maximum load on controller
12
MIDTX
3
%
Mid Tax
Mid load on controller
96
ERR2
3
Error 2
Second to last error 1)
97
ERR3
3
Error 3
Third from last error 1)
98
ERR4
3
Error 4
Fourth from last error 1)
10.2
The VAL Menu Parameters
This list displays all actual values and fixed values which can be accessed in the VAL menu.
AEach parameter is assigned a number which is required for control of the system via the serial
interface or InterBus-S. The MODE column shows the minimum user level from which there is
access to the display.
1) The error E-OFF is only stored if the mains voltage is restored within one minute.
2) Parameter IOSTA - status of inputs and outputs (hexadecimal).
VAL
ENPO
IS00
IS01
OS00
OS01
reserviert
reserviert
reserviert
ISA1
ISA0
(0001H)
(0002H)
(0004H)
(0008H)
(0010H)
(0200H)
(0100H)
(0080H)
(0040H)
(0020H)
1)
1)
1)
1) Only in case of digital
function of input/output
For bar chart display: parameter
BARG= IOSTA (_KPAD).
reserved