ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring Fault-tolerant PVCs
Configuring Fault-tolerant PVCs
Configuring Fault-tolerant PVCs
Use the following sequence to configure fault-tolerant PVCs:
Step 1.
Follow the sequence beginning on
to define a UNI DCE or UNI DTE
logical port as a backup port. In the General tab of the Add Logical Port dialog
box, select the check box for the Backup Service Name field (see
).
Step 2.
Define and specify a Service Name that will be bound to the primary port (see
Step 3.
Configure circuits to use the Service Name as an endpoint (see
). Note
that both endpoints can be different Service Names.
Step 4.
Define one or more backup logical ports (of the same type as the primary logical
port). When defining General Attributes for the backup logical port, select the
check box for the Backup Service Name field (see
).
Step 5.
(Optional) Activate one of the backup logical ports, as needed (see
Backup Binding Port” on page 14-6
Note – Lucent recommends that you avoid configuring SVCs on a logical port that is
also designated as a backup port in a fault-tolerant PVC configuration.
Note – You cannot use redirect PVCs with resilient UNI/NNI.