ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring Management Paths
Using MPVCs
Configuring an MPVC
The following sections describe how to define an MPVC connection and configure an
NMS path using a standard or redirect MPVC. To define a standard MPVC
connection, follow the instructions in the next section. To define a redirect MPVC
connection, follow the instructions on
.
Before you configure an MPVC, do the following:
1. Select the switch for which you want to configure the ATM UNI or NNI logical
port endpoint and define the physical port attributes. See the Switch Module
Configuration Guide
for CBX 3500, CBX 500, GX 550, and B-STDX 9000
for more
information.
2. Define an ATM UNI or NNI logical port. See
“Working With ATM Logical Ports”
Defining a Standard MPVC Connection
1. Open the object tree for a switch.
2. In the Network object tree, expand the instance node for the network that contains
the switch (see
3. Expand the LPorts class node and expand the instance node for the management
logical port named “
MgmtLPort.SW<
switchname>
” for Endpoint 1. The
<switchname>
should correspond to the name of the switch on which the
management port endpoint resides. The LPort Type field should display
Others:Multi Hop MPVC.
4. Expand the Circuits class node.
5. Select the PVCs class node and perform one of the following:
•
Select Add from the Actions menu.
•
Choose the Add button from the toolbar.
•
Right-click the PVCs class node and select Add from the pop-up menu.
The Add PVC dialog box appears (