![Lucent Technologies CBX 3500 Configuration Manual Download Page 535](http://html.mh-extra.com/html/lucent-technologies/cbx-3500/cbx-3500_configuration-manual_1946258535.webp)
Beta Draft Confidential
Configuring ATM Traffic Descriptors
Control Channel Default TDs
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
12-13
Control Channel Default TDs
Each type of control channel is initially configured with a set of default TDs. These
defaults specify the QoS class information and cell rate values for each TD type. See
the following tables to review these defaults:
•
Table 12-5, “UNI Signaling Control Channel TD Defaults,” on page 12-13
•
Table 12-6, “ILMI Control Channel TD Defaults,” on page 12-14
•
Table 12-7, “Trunk Control Channel TD Defaults,” on page 12-15
•
Table 12-8, “PNNI Routing Control Channel TDs,” on page 12-16
Table 12-5.
UNI Signaling Control Channel TD Defaults
DS1
E1
E3
DS3
OC-3c/
STM1
OC-12c/
STM4
Type
NoClpScr
a
a
The default Type, NoClpScr, represents the following: PCR CLP=0+1, SCR CLP=0+1, MBS
CLP=0+1.
NoClpScr
NoClpScr
NoClpScr
NoClpScr
NoClpScr
Class
VBR-NRT
VBR-NRT
VBR-NRT
VBR-NRT
VBR-NRT
VBR-NRT
PCR
b
(CPS)
b
If the configured logical port bandwidth is less than the physical port bandwidth, then PCR is
100% of logical port bandwidth.
3500
4700
13500
13500
13500
(CBX)
56000 (GX)
13500
(CBX)
56000 (GX)
SCR (CPS)
42
42
500
500
2000
8000
MBS (cells)
16
16
16
16
16
16
Approximate
EBW
c
(CPS)
c
The approximate equivalent bandwidth (EBW) values are based on the use of the default values
with the Lucent CAC in absence of user circuits on the logical port. It is provided here only as an
aid to determine how much total bandwidth is reserved for the control channel.The amount
reserved changes if you modify the TD class or value.
52
52
617
617
2468
9873
Summary of Contents for CBX 3500