ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
About ATM Logical Ports
About VP Shaping on the GX 550
Due to hardware restrictions, you cannot dynamically modify (enable or disable) the
configured VP shaping mode for BIO2 or BIO-C virtual UNI logical ports on which
circuits are provisioned. If you plan to enable VP shaping on virtual UNI logical ports,
Lucent recommends that you set the VP shaping attribute before configuring circuits
on the logical port.
To modify the VP shaping mode for GX 550 virtual UNI logical ports on which
circuits are provisioned, use the procedure described in
Mode on GX 550 Virtual UNI Logical Ports” on page 3-27
VP Shaping is not available when the BIO-C channelization mode is set to 48 x
STS-1. You cannot enable VP shaping for virtual UNI/NNI or OPTimum Trunk
logical ports configured on STS-1 subports.