Beta Draft Confidential
4-26
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring ATM Logical Ports on Frame-based Modules
Defining ATM UNI DCE/DTE Logical Ports
ILMI/OAM Attributes
Select the ILMI/OAM tab in the Add Logical Port dialog box (
) and
complete the fields as described in
Figure 4-4.
Add Logical Port: ILMI/OAM Tab
Table 4-10.
Add Logical Port: ILMI/OAM Tab Fields
Field
Action/Description
Enable
Select the check box to reserve a percentage of bandwidth in the VBR-NRT
QoS class for ILMI.
Clear the check box (default) to disable ILMI and not have reserve bandwidth.
If the attached device cannot run ILMI, leave ILMI disabled.
To receive ILMI VCC status traps from non-Lucent ATM UNI 3.1
devices, you must enable ILMI.
For information about ILMI support, see
Note: If you are using line loopback diagnostics, you must disable
ILMI support. See the Switch Diagnostics User’s Guide for CBX
3500, CBX 500, GX 550, and B-STDX 9000 for more information.
Summary of Contents for CBX 3500