ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring Trunks
Configuring VNN OSPF
3. In the Administrative tab in the Modify Switch dialog box, select one of the
following options in the PNNI Name Translation field:
•
Disabled — (default) Leave this check box unchecked to suppress flooding
of NAME(3) and SUMM_NM(3) LSAs for the specified switch. Use this
option if the switch does not need to interoperate with PNNI switches in your
network.
•
Enabled — Check this check box to enable flooding of NAME(3) and
SUMM_NM(3) LSAs for the specified switch. Use this option if the switch
must interoperate with PNNI switches in your network.
4. Choose OK to save your changes and close the dialog box.