Adjusting the CAC
Configuring the CAC
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
A-7
Beta Draft Confidential
Customizing the CAC for VBR-RT, VBR-NRT, and ABR
To customize the CAC for VBR-RT, VBR-NRT, and ABR:
1. In the Set All CAC Parameters dialog box (
Customized VBRrt, VBRnrt, and ABR in the CAC Type field.
2. In the Port Scale Factors field, enter a scale factor percentage to use for computing
bandwidth requirements on the physical port.
For example, if you enter a value of 125% in the DS3 field, a circuit that would
normally reserve bandwidth based on an SCR of 10,000 CPS would be
allocated bandwidth of 12,500 CPS.
3. To customize the CAC based on the SCR and MBS values, use the SCR Limit
Scale Factors field:
Summary of Contents for CBX 3500