Configuring SVC Parameters
Configuring SVC Port Addresses
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
17-61
E.164 AESA SVC Address Format
Complete the following fields for the E.164 AESA SVC address format:
Figure 17-32.
Add SVC Port Address: E.164 AESA Format
1. If you want to create the address manually, continue with the steps a, b, and c
below. If you want to use the Auto ESI Assignment feature to create the address,
go to
below.
a. In the E.164 field, enter the full or partial E.164 AESA address. Since the IDI
portion of the address is 8 octets (16 hex digits), but the E.164 address format
is a maximum of 15 digits, you must terminate the IDI portion with F. For
example, enter 5085551234 as 000005085551234F.
b. After you type the IDI portion of the address, enter the appropriate HO-DSP,
ESI, and SEL portions to complete the address. For information on the
appropriate format to use for E.164 AESA addresses, see
c.
See
to configure additional fields. Go to
2. Select the check box for the Use Auto ESI Assignment field. The address will be
filled in automatically.(
3. Choose OK to save the SVC port address and close the dialog box.