About Trunk Conditioning
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
1/19/05
I-3
Beta Draft Confidential
Configuration Values in the Downstream Direction
The configuration shown in
in the Tx (ingress) direction when alarms are
present results in the data as 0x7F and signaling values “ABCD” as 1010 to be sent in
downstream direction.
Note – Tx and Rx conditioning modes are independent of each other.
Table I-2.
Example of Trunk Conditioning Values in Downstream
Direction
Field
Value
Configuration Value
Tx Conditioning Data
0 to 0xFF
0x7F
Tx Conditioning Signal
0 to 0xF
0xA
Tx Conditioning Mode
1 (None)
2 (Data and Signaling)
3 (Data)
4 (Signalling)
2 (Data and Signaling)
default
Tx Force Conditioning Mode
1 (None)
2 (Data and Signaling)
3 (Data)
4 (Signaling)
1 (None) default
Summary of Contents for CBX 3500