Beta Draft Confidential
14-6
1/19/05
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring Fault-tolerant PVCs
Activating a Backup Binding Port
Activating a Backup Binding Port
If a primary port fails (or needs administrative maintenance), you reassign the Service
Name of the primary port to a backup port. Since fault-tolerant PVCs use the Service
Name as an endpoint, circuits configured for the primary port are rerouted to the
backup port.
To activate a backup LPort for a service name:
1. Expand the instance node of the LPort where the service name binding is located.
The Service Names class node appears under the LPort instance node.
2. Expand the class node for the Service Names.
3. Right-click on the service name you want to activate and select Modify from the
pop-up menu. The Modify Service Name dialog box appears (
Figure 14-2.
Modify Service Name Dialog Box
4. Clear the check box in the Enabled Primary Binding field.
5. Choose the Select Backup LPort button. The Select Backup LPort dialog box
appears (