Installing the Inverter
44
Output/Communication Terminal Labels and Descriptions
Function
Label
Name
Description
Analog output
AO, AO1
Voltage/Current
Output
Used to send inverter output information to
external devices: output frequency, output
current, output voltage, or a DC voltage.
Operate switch (SW3) to select the signal
output type (voltage or current) at the AO
terminal.
Output Signal Specifications:
•
Output voltage: 0–10V
•
Maximum output voltage/current:
12V/10mA
•
Output current: 0–20mA
•
Maximum output current: 24mA
•
Factory default output: Frequency
AO2
Analog voltage
output terminal
Use to send inverter output information, such as
output frequency, output current, output voltage,
or DC voltage to external devices.
•
Output voltage: 0
–
10 V
•
Maximum output voltage/current: 12V/10 mA
TO
Pulse Output
Sends pulse signals to external devices to
provide a single output value from the inverter of
either: output frequency, output current, output
voltage, or DC voltage.
Output Signal Specifications:
•
Output frequency: 0–32kHz
•
Output voltage: 0–12V
•
Factory default output: Frequency
(In case of Standard I/O, Pulse output TO and
Multi-function output Q1 share the same
terminal. Set the OU.33Q1 Define to 38(TO).)
When connecting to a pulse between the S100
inverters,
•
Multiple I/O< -> Multiple I/O : Connect to
TO -> TI, CM -> CM
•
Standard I/O <-> Standard I/O : Connect to
Q1 -> P5, EG -> CM
•
Multiple I/O <-> Standard I/O : Do not
support.
Digital output
Q1
Multi-functional
(open collector)
DC 26V, 100mA or less
Factory default output: Run
EG
Common
Common ground contact for an open collector
(with external power source)
24
External 24V
Maximum output current: 150mA
Summary of Contents for LSLV-S100 Series
Page 1: ......
Page 11: ...Preparing the Installation 2 ...
Page 13: ...Preparing the Installation 4 5 5 22kW 3 Phase ...
Page 16: ...Preparing the Installation 7 Front cover removed ...
Page 45: ...Installing the Inverter 36 IP66 0 4 0 8kW 3 phase 1 5 2 2kW 3 phase ...
Page 50: ...Installing the Inverter 41 0 4 22kW Standard I O Multiple I O ...
Page 67: ...Installing the Inverter 58 ...
Page 69: ...Learning to Perform Basic Operations 60 30 75kW Models ...
Page 193: ...Table of Functions 184 ...
Page 205: ...196 Troubleshooting ...
Page 228: ...Technical Specification 219 30 75kW Models 30 kW 3 Phase 37 45 kW 3 Phase ...
Page 230: ...Technical Specification 221 IP66 Models 0 4 4 0kW NP Non PDS type ...
Page 231: ...Technical Specification 222 0 4 4 0kW PDS type ...
Page 233: ...Technical Specification 224 5 5 7 5kW NP Non PDS type ...
Page 235: ...Technical Specification 226 11 0 22 0kW NP Non PDS type ...
Page 259: ...250 ...
Page 261: ...252 ...
Page 263: ...254 ...